Two additional technical dynamics exacerbate escalation risk during a cyber-physical crisis:
First, compromised sensors and spoofed operator telemetry can blind human decision-makers to physical reality4. In Stuxnet, the malware replayed pre-recorded normal frequency values (1,064 Hz) to the operator HMI screens while the physical centrifuges were spinning at destructive speeds (1,410 Hz and 2 Hz)119. In TRITON, the malware masqueraded as legitimate trilog.exe diagnostic software while modifying safety controller firmware in RAM4. Conversely, in the Cyber-Informed Engineering Implementation Guide, DOE and INL engineers note that if a vibration monitoring sensor on a turbine generator fails or is manipulated so it fails to detect an overworn bearing, the physical equipment suffers catastrophic mechanical destruction and a prolonged outage29. If national security decision-makers or automated defense systems rely purely on digital telemetry from a compromised network without independent out-of-band analog sensors, they can either fail to respond to an active physical meltdown or be tricked by spoofed digital alarms into believing an infrastructure plant is under destructive attack when the physical process is completely stable4.
Second, the proliferation of the international commercial offensive cyber supply chain frequently causes "bug collisions" that corrupt technical attribution95. In a comprehensive 2024–2025 investigation (Crash, Exploit, and Burn), the Atlantic Council mapped 49 commercial offensive cyber capability vendors, 36 subsidiaries, 24 partner firms, 20 suppliers, 32 holding companies, 95 investors, and 179 individuals operating across every inhabited continent (with high concentrations in Israel, Italy, and India) that develop and sell bespoke zero-day exploits (which require 6 to 18 months of full-time engineering research to create), malware payloads, and command-and-control infrastructure to sovereign intelligence agencies and militaries95. Because commercial middlemen and brokers operate with high opacity, government buyers often do not know if a commercial vendor has resold an overlapping capability to another state, or if a second state independently discovered the same vulnerability95. As the Atlantic Council report warns, such bug collisions mean that a single zero-day exploit is used by multiple distinct actors, creating a high risk of false attribution by private threat intelligence firms or government analysts who assume that an exploit belongs exclusively to one nation-state95.
6. Protective Alternatives: Cyber-Informed Engineering, Isolation, Continuity, and Intergovernmental Cooperation
Research Question 6 asks what protective alternatives exist through isolation, recovery, continuity, and intergovernmental cooperation. Because the jus ad bellum principle of necessity (Tallinn Manual 2.0 Rule 72) strictly forbids resorting to military force whenever passive or non-forceful defenses can thwart a cyber armed attack8, and because false flags and logging gaps make retaliatory deterrence perilous22, the primary strategic imperative for states is to engineer life-sustaining infrastructure so that digital compromises cannot physically translate into mass human casualties29.
6.1 Cyber-Informed Engineering (CIE) and Physics-Based Safety Overrides
Developed by the U.S. Department of Energy's (DOE) Office of Cybersecurity, Energy Security, and Emergency Response (CESER) and the Idaho National Laboratory (INL)—and codified in the June 2022 National Cyber-Informed Engineering Strategy, the Cyber-Informed Engineering Implementation Guide (Version 1.0), and NIST Special Publication 800-82 Rev. 3 (aligned with the ISA/IEC 62443 industrial security standard series, specifically IEC 62443-3-2 on risk assessment for Systems under Consideration)—Cyber-Informed Engineering (CIE) and Consequence-Driven Cyber-Informed Engineering (CCE) fundamentally transform critical infrastructure defense29.
Rather than treating cybersecurity as an after-the-fact software layer bolted onto an already-built plant, CIE integrates cybersecurity across a seven-phase systems engineering lifecycle (with three continuous controlling processes), extending "secure-by-design" principles beyond software to secure cyber-physical systems using physics and mechanics, not just digital monitoring and controls29. Under CIE Principle 1 (Consequence-Focused Design), engineers assume that a sophisticated nation-state adversary will eventually gain administrative access to the digital network and ask how the physical and mechanical architecture of the system can be designed so that worst-case sabotage cannot cause catastrophic physical consequences29.
Applied across the energy, water, and industrial sectors, CIE and federal joint advisories (such as CISA/FBI/EPA advisory AA21-042A following Oldsmar and DOE/CISA advisories following TRITON) establish five concrete engineering defenses4:
- Deterministic Mechanical and Analog Safety Overrides: To prevent an Oldsmar-style chemical poisoning or a German steel mill blast furnace meltdown, physical process boundaries must be enforced by non-digital hardware that cannot be reprogrammed over a network22. In municipal water treatment plants, utilities install physical orifice plates or mechanical stroke limiters on chemical dosing pumps so that even if a hacker sets the SCADA HMI to 11,100 ppm of sodium hydroxide, the physical pump mechanically cannot inject a lethal dose, backed by independent hardwired analog pH sensors that mechanically trip the feed valve if alkalinity exceeds safe drinking thresholds3. In high-pressure boilers, chemical reactors, and blast furnaces, spring-loaded mechanical pressure relief valves, fusible thermal plugs, and centrifugal mechanical overspeed governors physically vent pressure or cut fuel regardless of PLC commands29.
- Physical Hardware Key-Switch Locks on Safety Instrumented Systems (SIS): As the 2017 TRITON intrusion proved, attackers could only inject malicious firmware into the Schneider Electric Triconex safety controllers because the physical key-switch on the controller cabinet had been left in PROGRAM mode4. Under ICS security best practices, plant operators must physically turn all SIS controller key-switches to RUN mode, remove the physical keys to a locked vault, continuously monitor key-switch state transitions in the historian, and treat any request to switch a controller to PROGRAM mode as a strictly audited physical maintenance event4.
- Unidirectional Gateways (Optical Data Diodes) and Industrial DMZs: To prevent corporate spearphishing or ransomware (like IcedID, Ryuk, or BlackEnergy) from pivoting into Operational Technology (OT) or SIS zones, control networks must be segmented behind an Industrial Demilitarized Zone (IDMZ)4. Where operational telemetry must be transmitted from safety-critical PLCs or SIS controllers to corporate historians for monitoring, facilities should deploy unidirectional gateways (optical data diodes)—hardware devices that physically transmit light pulses in only one direction—making it physically impossible for external network traffic or remote commands to enter the control network, while providing remote users with view-only access to mirrored process data4.
- Hardened Remote Access Gateways, Named Accounts, and Protocol-Level Verification: As demonstrated by both Oldsmar and the 2022 Viasat KA-SAT hack (where a misconfigured VPN enabled mass modem wiping), ad-hoc remote desktop software (TeamViewer) and shared passwords must be eradicated22. All remote vendor or engineer sessions must pass through a single, guarded gateway requiring individual named accounts, hardware-backed Multi-Factor Authentication (MFA), and zero-trust packet verification where traffic from unverified machine identities is rejected at the protocol layer5.
- Autonomous Local Control Loops and Manual Operations Readiness: As seen when 5,800 ENERCON wind turbines continued generating over 10 GW of electricity safely after the 2022 Viasat AcidRain wiper severed their satellite SCADA links, and when Ukrainian substation engineers manually restored power in 2015, critical infrastructure must be engineered so local controllers maintain safe steady-state operation when wide-area communications drop, and staff must regularly drill manual physical operation using analog gauges and hand-wheels2.
6.2 Network Micro-Segmentation, Timed Restoration, and Clinical Continuity in Healthcare
In acute-care hospitals—where the threat to human life arises primarily from the sudden loss of diagnostic pathology, imaging, radiation therapy, and electronic patient records during ransomware encryption—the official post-incident audits of WannaCry (NAO, 2017), HSE Ireland (PwC and C&AG, 2021), and NHS Synnovis (2024–2026) provide a blueprint for clinical survival without retaliation5:
First, healthcare systems must eliminate flat network architectures and enforce strict micro-segmentation142. In the 2021 HSE Ireland attack, a single malicious Excel attachment opened on one workstation forced the shutdown of 70,000 devices across 4,000 locations because the National Healthcare Network lacked internal segmentation firewalls between corporate email, active directory domains, and hospital clinical systems16. Notably, during that same attack, two connected organizations ("Hospital A" and the Department of Health) detected the Conti attacker's lateral movement between May 8 and May 12 and proactively severed their network links, successfully preventing ransomware deployment within their estates100. Similarly, following WannaCry, the NHS deployed the NHS Secure Boundary (next-generation perimeter and web application firewalls) and centralized endpoint detection across 1.3 million connected devices146.
Second, healthcare authorities must extend mandatory security standards and continuity redundancies to third-party clinical supply chains5. As the 2024 Synnovis crisis demonstrated, WannaCry taught the NHS to patch its own Windows systems, but Qilin crippled six London NHS trusts by striking an external private pathology company that processed 10,000 blood tests per day and lacked MFA on its entry portals5. Implementing the UK's Cyber Security and Resilience Bill and the January 2026 Government Cyber Action Plan, hospitals must audit critical diagnostic suppliers, disable browser password storage via Group Policy, enforce MFA across all external portals, and maintain interoperable backup laboratory pathways and regional O-negative blood reserves5.
Third, as the Irish Comptroller and Auditor General Audit of the HSE attack emphasized, "A backup is not a recovery plan... The test that counts is a restore, performed and timed, not a backup taken"142. Because modern ransomware strains like Qilin.B and wipers like NotPetya and Olympic Destroyer are engineered so that decryption without a key is mathematically impossible (and commercial "ransomware decryption" services frequently either fail or secretly pay the ransom on the victim's behalf), hospitals must maintain offline, immutable backups and regularly time bare-metal restoration of domain controllers, LIMS, and EHR databases2.
Fourth, hospitals must institutionalize realistic clinical downtime triage and post-outage record reconciliation protocols69. Reverting to pen and paper during a 130-day (HSE Ireland) or 180-day (Synnovis) outage creates acute patient-safety risks: when central obstetrical or ICU telemetry is offline (as alleged at Springhill Medical Center) or emergency diagnostics are unavailable (as at Düsseldorf University Hospital), hospital leadership must transparently declare a critical incident and divert high-acuity ambulances rather than admitting patients into a blinded clinical environment5. Furthermore, because the Synnovis attack left 161,560 paper and temporary pathology reports unentered into NHS electronic patient records as of January 2026, continuity plans must designate accountable clinical teams to reconcile manual downtime records back into the permanent EHR once systems are restored69.